Heat Pump Sizing and Home Suitability

Home suitability for a heat pump comes down to the Heat Loss Indicator, a measure of how fast a dwelling loses heat through its fabric and ventilation. TU Dublin research found roughly 3 in 4 Irish homes are already suitable, and most of the remaining quarter can qualify with insulation upgrades.

≤2.0standard HLI target, W/(K·m²)
≤2.3exception ceiling, conditions apply
~75%of Irish homes already suitable
The core metric

What the Heat Loss Indicator Measures

The Heat Loss Indicator is a dwelling’s total fabric and ventilation heat loss, divided by its floor area, calculated using SEAI’s DEAP software during a BER assessment.

HLI = (Fabric Heat Loss + Ventilation Heat Loss) ÷ Floor Area

Expressed in watts per Kelvin per square metre, W/(K·m²). Lower means the home retains heat better.

A concrete example: a 100 sqm home at HLI 2.3, with 20°C inside and 5°C outside, loses roughly 3,450 watts through its fabric and ventilation. The lower the HLI, the less a heat pump has to work to hold that temperature.

Qualifying thresholds

HLI Thresholds for the SEAI Grant

ThresholdHLI valueCondition
Standard target≤2.0 W/(K·m²)Qualifies without further conditions
Exception ceiling≤2.3 W/(K·m²)Accepted where additional SEAI requirements are met
Rough BER equivalentC1–C3Varies by house type and construction

Most guidance simplifies this to “HLI 2.3 or below,” since that’s the outer edge of what can qualify. The clean target SEAI actually designs the grant around is 2.0, worth knowing if a home sits in that 2.0–2.3 band and extra conditions come up during assessment.

Base rates

Is a Given Home Likely Suitable

Suitability tracks three things: how well insulated the home is, its age, and its current heating system.

~75%
of Irish homes already meet the HLI target
~25%
need insulation work first, most can then qualify
10yr
a valid BER stays usable to check current HLI

A home’s current HLI is visible on its existing BER, if it has one under 10 years old. Look it up on SEAI’s BER database using the property’s MPRN before booking a survey.

Assessment process

How the Suitability Assessment Works

1

Check for an existing BER

Homes built before 2007 with a valid, current BER already showing an HLI at or below 2.3 can skip a full Technical Assessment and submit a Self-Declaration form instead.

2

Technical Assessment, where needed

An SEAI-registered Technical Advisor, a BER assessor with additional qualification specific to this role, evaluates insulation, windows and doors, thermal bridging, and air tightness.

3

HLI result and recommendations

The Technical Advisor reports the current HLI and, if it’s above target, the specific upgrades that would bring it down.

4

Insulation work, if required

Attic, cavity wall, or external wall insulation, itself grant-funded separately, reduces fabric heat loss and lowers the HLI.

5

Heat pump sizing

Once eligible, the installer calculates the property’s peak heat loss to size the unit correctly, not simply fitting a standard capacity.

Beyond eligibility

Why Correct Sizing Matters

An undersized heat pump struggles to reach temperature on the coldest days and relies more on backup electric heating, raising running costs. An oversized one short-cycles, switching on and off more often than it should, which wears components faster and cuts efficiency.

Installer sizing decisions, not the equipment itself, cause most of the complaints homeowners report after a heat pump install. A proper survey calculates the home’s actual peak heat loss rather than estimating from floor area alone.

If a home doesn’t qualify yet

Getting a Home Heat Pump Ready

•Attic insulation is usually the lowest-cost, highest-impact upgrade, and is separately grant-funded.
•Cavity or external wall insulation addresses homes losing significant heat through solid or poorly insulated walls.
•Insulation work happens first, then a heat pump application goes in, not the other way round.
•The Technical Advisor’s report specifies exactly which upgrades would bring a given home’s HLI into range.
Questions

Sizing and Suitability Questions

How do I find my home’s current HLI?

Check SEAI’s BER database using the property’s MPRN, if a valid BER under 10 years old exists. Otherwise, a new BER assessment establishes it.

Does every home need a full Technical Assessment?

No. Homes built before 2007 with a current BER already showing HLI at or below 2.3 can use a Self-Declaration form instead of a full assessment.

What if my home’s HLI is above 2.3?

Insulation work, attic, cavity wall, or external wall, brings the HLI down. These measures carry their own SEAI grants, separate from the heat pump grant.

Is a bigger heat pump always better?

No. An oversized unit short-cycles and loses efficiency. Correct sizing comes from the home’s actual calculated heat loss, not the largest available unit.

Get started

Find Out If a Home Qualifies

An SEAI-registered installer checks the current HLI and confirms next steps during survey.